-
Safe-T-Alert Safe-T-Alert Combo Carbon Monoxide Propane Alarm - Flush Mount - Mini - Black [25-742-BL]
Combo Carbon Monoxide Propane Alarm - Surface Mount - Mini - BlackHave a safe TRIP!Test and inspect the Propane and CO alarms installed in your RV every week and replace malfunctioning alarms.Replace all Propane and CO alarms that are 5 years old or older.Install alarms listed for RV use.Prevent accidents by teaching family and friends about the operation of the alarms. Never ignore a sounding alarm.Features: Double-Duty Alarm. Upgrades single 12 Volt Propane Gas alarms to a dual alarm that detects both Propane Gas and CO Space Saving. Compact design for RV's Designed for the Rugged RV Environment. Ideal for Class A Motor homes, Class B Van Campers, Class C Mini-Motor Homes, Travel Trailers, Fifth Wheels, Truck & Folding Campers Advanced Technology. Alarm Mute button silences alarm while RV is ventilated. Rapid recovery sensor resets when silenced or reactivates alarm if dangerous levels of Propane or CO remain Reliable. 12 Volt power means no missing or dead batteries to replace Approved. Meets RVIA/NFPA requirements Listed to UL 1484 RV and UL 2034 RV Specifications: Fume Type: Carbon Monoxide Voltage - Input Range (Volts): 12v Generator Shutdown: No Box Dimensions: 2"H x 8"W x 10"L WT: 0.4 lbs UPC: 715456257440
$68.99
-
Fireboy-Xintex Fireboy-Xintex Optical Smoke Detector w/Base [OMSD-01-DB-R]
Optical Smoke Detector with BaseOptical smoke detectors have consistently been recognized as suitable detectors for general use. They are regarded as particularly suitable for smoldering fires and escape routes. This smoke detector is also designed to significantly reduce the incidence of false alarms through over-sensitivity to transient phenomena.Features: Recommended for use as general-purpose smoke detectors for early warning of fires in most areas Works well in black as well as in white smoke Compensation for slow changes in sensitivity Extra confirmation of smoke before an alarm signal is given Specifications: Sampling Frequency: Once every four seconds Operating Voltage: 8.5 V dc to 33 V dc Supply Wiring: Two wire supply, polarity sensitive Power-up Time: < 20 seconds Minimum ‘Detector Active’ Voltage: 6 V Minimum Holding Current: 8 mA Minimum Voltage to Light Alarm LED: 5 V Alarm Reset Time: One second Alarm Indicator: Integral indicator with 360º visibility Operating & Storage Temperature: -40ºC to +70ºC Humidity (no condensation or icing): 0% to 98% RH Operation: Optical Smoke Detectors work on the well-established light scatter principle The remarkable optical design of this Smoke Detector enables it to respond to a wide spectrum of fires The sensing chamber contains an optical sensor that measures back-scattered light as well as the more usual forward-scattered light The detector is calibrated so that it is highly reliable in detecting fires but is much less likely to generate false alarms The stability of the detector-high reliability, low false alarm rate is further increased by the use of algorithms to decide when the detector should change to the alarm state Removes the likelihood of a detector producing an alarm as a result of smoke from smoking materials or another non-fire source Specifications: Fume Type: Smoke Box Dimensions: 2"H x 5"W x 7"L WT: 0.35 lbs UPC: 619749321095
$160.99
-
Fireboy-Xintex Fireboy-Xintex Gasoline Fume Detector - Chrome Bezel - 12/24V [G-1C-R]
Gasoline Fume Detector - Chrome Bezel - 12/24VThe Single Channel Gasoline Fume Detector is an effective means to monitor gasoline fumes in an engine compartment, fuel tank storage area or in other areas where gasoline fumes might accumulate. Features: Simple Installation Audible and visual alarm to indicate LEL (Lower Explosive Level) presence Monitors one (1) single area Technical Specifications: Operating Temperature: -40° to 185°F (-40° to 85°C) Current Draw Nominal - 55mA Current Draw Maximum - 95mA Operating Voltage - 9 to 30V DC Alarm Horn - 68 dB Display Style - Round with Chrome Bezel Display Dimensions - 2-3/16" (5.6 cm) round Cutout Dimension - 2-1/16" (5.2 cm) round hole In the Box: Fume Detector Fuel sensors x one (1) 20' Extension Cable x one (1) Instruction manual *Sold as an Individual Specifications: Blower Relay: No Fume Type: Gasoline Generator Shutdown: No Sensors Included: 1 Voltage - Input Range (Volts): 9 to 30 Box Dimensions: 4"H x 4"W x 8"L WT: 1 lbs UPC: 619749202530 Owner's Manual (pdf)Brochure (pdf)
$333.99
-
Fireboy-Xintex Fireboy-Xintex Gasoline Fume Detector w/Dual Channel Blower Control - 12/24V [G-2BB-R]
Gasoline Fume Detector with Dual Channel and Blower Control - 12/24VThe Dual Channel Gasoline Fume Detector is an effective means to monitor gasoline fumes in an engine compartment, fuel tank storage area or in other areas where gasoline fumes might accumulate. Complete system includes Blower Control Relay, easy installation and precise monitoring. Features: Simple Installation Audible and visual alarm to indicate LEL (Lower Explosive Level) presence Monitors two (2) separate areas simultaneously Automatically activates bilge blower Technical Specifications: Operating Temperature: -40° to 185°F (-40° to 85°C) Current Draw Nominal - 55mA Current Draw Maximum - 150mA Operating Voltage - 9 to 30V DC Alarm Horn - 68 dB Display Style - Square with Black Bezel Display Dimensions - 2-5/8" x 2-5/8" (6.7 x 6.7 cm) Cutout Dimension - 2-1/8" (5.4 cm) round hole In the Box: Fume Detector Fuel sensors x two (2) 20' Extension Cable x two (2) Blower Relay x one (1) Instruction manual *Sold as an Individual Specifications: Blower Relay: Yes Fume Type: Gasoline Generator Shutdown: No Sensors Included: 2 Voltage - Input Range (Volts): 9-30v Box Dimensions: 4"H x 4"W x 8"L WT: 1.6 lbs UPC: 619749202561 Owner's Manual (pdf)Brochure (pdf)
$600.99
-
Safe-T-Alert Safe-T-Alert Combo Carbon Monoxide Propane Alarms Flush Mount - Black [35-742-BL]
Combo Carbon Monoxide Propane Alarms Flush Mount - BlackHave a safe TRIP!Test and inspect the Propane and CO alarms installed in your RV every week and replace malfunctioning alarms.Replace all Propane and CO alarms that are 5 years old or older.Install alarms listed for RV use.Prevent accidents by teaching family and friends about the operation of the alarms. Never ignore a sounding alarm.Features: Double-duty alarm - Detects both gas leaks and CO gas simultaneously Reliable - 12V power means no missing or dead batteries to replace Durable - Built for the extreme RV environment Approved - Meets RVIA/NFPA requirements End of Life Signal Specifications: Voltage - Input Range (Volts): 12v Generator Shutdown: No Fume Type: Carbon Monoxide Box Dimensions: 2"H x 8"W x 10"L WT: 0.5 lbs UPC: 715456357447
$75.99
-
Fireboy-Xintex Fireboy-Xintex Gasoline Fume Detector w/Blower Control - Chrome Bezel - 12V [G-1CB-R]
Gasoline Fume Detector w/Blower Control - Chrome Bezel - 12VThe Single Channel Gasoline Fume Detector is an effective means to monitor gasoline fumes in an engine compartment, fuel tank storage area or in other areas where gasoline fumes might accumulate. Complete system includes Blower Control Relay, easy installation and precise monitoring. Features: Simple Installation Audible and visual alarm to indicate LEL (Lower Explosive Level) presence Monitors one (1) single area Automatically activates bilge blower Technical Specifications: Operating Temperature: -40° to 185°F (-40° to 85°C) Current Draw Nominal - 55mA Current Draw Maximum - 95mA Operating Voltage - 9 to 30V DC Alarm Horn - 68 dB Display Style - Round with Chrome Bezel Display Dimensions - 2-3/16" (5.6 cm) round Cutout Dimension - 2-1/16" (5.2 cm) round hole In the Box: Fume Detector Fuel sensors x one (1) 20' Extension Cable x one (1) Blower Relay x one (1) Instruction manual *Sold as an Individual Specifications: Blower Relay: Yes Fume Type: Gasoline Generator Shutdown: No Sensors Included: 1 Voltage - Input Range (Volts): 9 to 30 Box Dimensions: 4"H x 4"W x 8"L WT: 1 lbs UPC: 619749202547 Owner's Manual (pdf)Brochure (pdf)
$365.99
-
Fireboy-Xintex Fireboy-Xintex Gasoline Fume Detector - Black Bezel - 12/24V [G-1B-R]
Gasoline Fume Detector - Black Bezel - 12/24VThe Single Channel Gasoline Fume Detector is an effective means to monitor gasoline fumes in an engine compartment, fuel tank storage area or in other areas where gasoline fumes might accumulate. Features: Simple Installation Audible and visual alarm to indicate LEL (Lower Explosive Level) presence Monitors one (1) single area Technical Specifications: Operating Temperature: -40° to 185°F (-40° to 85°C) Current Draw Nominal - 55mA Current Draw Maximum - 95mA Operating Voltage - 9 to 30V DC Alarm Horn - 68 dB Display Style - Round with Black Bezel Display Dimensions - 2-3/16" (5.6 cm) round Cutout Dimension - 2-1/16" (5.2 cm) round hole In the Box: Fume Detector Fuel sensors x one (1) 20' Extension Cable x one (1) Instruction manual *Sold as an Individual Specifications: Blower Relay: No Fume Type: Gasoline Generator Shutdown: No Sensors Included: 1 Voltage - Input Range (Volts): 9 to 30 Box Dimensions: 4"H x 4"W x 8"L WT: 1 lbs UPC: 619749202516 Owner's Manual (pdf)Brochure (pdf)
$322.99
-
Fireboy-Xintex Fireboy-Xintex Fixed Heat Detector w/Base [OMHD-04-DB-R]
Fixed Heat Detector with BaseThe Fireboy-Xintex Heat Detector uses a single thermistor to sense the air temperature around the detector. This heat detector was designed to detect how fast the temperature is increasing.Features: 163°F Fixed Heat Detector Housing: White flame-retardant polycarbonate Terminals: Nickel-plated stainless steel Ideal in environments that are dirty or smoky Unaffected by wind or atmospheric pressure Remote test feature Specifications: Detection Principle: Measurement of heat using a thermistor Sampling Frequency: Once every four seconds Supply Voltage: 8.5 V dc to 33 V dc Supply Wiring: Two wire supply, polarity sensitive Power-up Time: < 20 seconds Minimum: ‘detector active’ voltage: 6 V Holding Voltage: 5 V - 33 V Minimum Holding Current: 8 mA Minimum Voltage to Light Alarm LED: 5 V Alarm Reset Voltage: < 1 V Alarm Reset Time: One second Alarm Indicator: Integral indicator with 360º visibility Operating & Storage Temperature: -40ºC to +70ºC Operation: Open-web casing that enables air to flow freely across a thermistor which measures the air temperature every two seconds A microprocessor stores the temperatures and compares them with pre-set values to determine whether a fixed upper limit - the alarm level - has been reached Detectors the microprocessor uses algorithms to determine how fast the temperature is increasing
$145.99