
-
Fireboy-Xintex Fireboy-Xintex MA Series Fire Extinguishing System - 450 Cubic Feet [MA20450227-BL]
MA Series Fire Extinguishing System - 450 Cubic FeetFireboy-Xintex clean agent fire extinguisher systems are designed to automatically discharge whenever the protected space's ambient temperature reaches 175 degrees Fahrenheit.When the Fireboy System discharges, the extinguisher is designed to fully empty the HFC-227ea (Heptafluoropropane) and 3M Novec Clean Agent in less than 10 seconds. No clean-up is required. There is no powdery residue or water left behind. The fire is extinguished by a combination of heat reduction and chemical reactions.*Diesel-powered craft require installation of an Engine Shutdown System Features: Protects engine rooms and machinery spaces Pre-engineered, total flooding system The safest way to combat an engine room fire Automatic discharge at 175°F (79°C) with optional manual release Utilizes HFC-227ea and 3M Novec clean agents – an effective Halon replacement No water or powdery residue Includes locking lever for increased safety when removing or installing cable Certifications: U.S.C.G. EN ISO 9094-1 and 9094-2 standards ISO RINA MCA Certified Factory Mutual Technical Specifications: Volume Protected - 450 ft3 Dimensions (Dia. x H) - 7.1" x 19.4" (18 x 49.3 cm) Agent - HFC-227ea and 3M Novec Agent Weight - 19.4 lbs (8.8 kg) System Pressure (@70°F) - 240 psi In the Box: Fire extinguisher Mounting bracket Helm station panel - 90107 Owners manual *Sold as an Individual Owner's Manual (pdf)Brochure (pdf)
$2,250.00 $1,389.99
-
Fireboy-Xintex Fireboy-Xintex Two Zone Detection Alarm Panel - 2-5/8" Display - 12/24V DC [FBD-2-R]
Two Zone Detection & Alarm Panel - 2-5/8" Display - 12/24V DCEach system consists of a monitor panel and up to 14 smoke or heat detectors and/or rate of rise heat detectors connected to each zone (sold separately.)Features: Visual and audible indications of a fire or fault Water resistant display Voltage and EMI protected Reverse polarity protected Specifications: Supply Voltage: 9-32V DC Zone Loop Voltage: 24V DC (regardless of input voltage) Minimum Alarm Current: 15mA Maximum Current Per Zone: 400mA Maximum Sensors Per Zone: 8 EOL Resistor: 5.6kΩ Potential Free Transistor Output (Fault, Alarm): 50V max Relay Output (Buzzer): 2A Owner's Manual (pdf)
$975.00 $572.99
-
Fireboy-Xintex Fireboy-Xintex 8 Circuit Engine Shutdown w/Time Delay - Round Display [ES-8015-01]
8 Circuit Engine Shutdown with Time Delay - Round DisplayFeatures:Required for Diesel EnginesEach engine shutdown display unit comes with: Integrated alarm horn Charged/discharged lights Override switch for restart or control of auto-shutdown Additional units and wire harnesses are available for a second station
$950.00 $558.99
-
Fireboy-Xintex Fireboy-Xintex Propane Fume Detector, 2 Channel, 2 Sensors, Solenoid Valve Control 20 Cable - 24V DC [P-2BS-24-R]
Propane Fume Detector, 2 Channel, 2 Sensors, Solenoid Valve & Control & 20' Cable - 24V DC Propane has become the fuel of choice for cooking and heating.Highly BTU-efficient and readily available, propane is becoming more and more a part of power boating, sailing, and camping. The Xintex® line of propane products includes everything you need for outfitting a complete and safe propane system.Propane is heavier than air and can settle below deck and in the bilge where it can be detonated by an engine start-up or electrical spark of any kind. Xintex® Propane Fume Detectors will alarm when fumes reach 18-20% LEL. *Includes Time Sensor Valve Owner's Manual (pdf)Brochure (pdf)
$875.00 $514.99
-
Fireboy-Xintex Fireboy-Xintex Gasoline Fume Detector w/Dual Channel Blower Control - 12/24V [G-2BB-R]
Gasoline Fume Detector with Dual Channel and Blower Control - 12/24VThe Dual Channel Gasoline Fume Detector is an effective means to monitor gasoline fumes in an engine compartment, fuel tank storage area or in other areas where gasoline fumes might accumulate. Complete system includes Blower Control Relay, easy installation and precise monitoring. Features: Simple Installation Audible and visual alarm to indicate LEL (Lower Explosive Level) presence Monitors two (2) separate areas simultaneously Automatically activates bilge blower Technical Specifications: Operating Temperature: -40° to 185°F (-40° to 85°C) Current Draw Nominal - 55mA Current Draw Maximum - 150mA Operating Voltage - 9 to 30V DC Alarm Horn - 68 dB Display Style - Square with Black Bezel Display Dimensions - 2-5/8" x 2-5/8" (6.7 x 6.7 cm) Cutout Dimension - 2-1/8" (5.4 cm) round hole In the Box: Fume Detector Fuel sensors x two (2) 20' Extension Cable x two (2) Blower Relay x one (1) Instruction manual *Sold as an Individual Specifications: Blower Relay: Yes Fume Type: Gasoline Generator Shutdown: No Sensors Included: 2 Voltage - Input Range (Volts): 9-30v Box Dimensions: 4"H x 4"W x 8"L WT: 1.6 lbs UPC: 619749202561 Owner's Manual (pdf)Brochure (pdf)
$875.00 $514.99
-
Fireboy-Xintex Fireboy-Xintex Propane Fume Detector Alarm w/2 Plastic Sensors Solenoid Valve - Square Black Bezel Display [P-2BS-R]
Propane Fume Detector & Alarm w/2 Plastic Sensors & Solenoid Valve - Square Black Bezel DisplayDetect propane leaks early and automatically shut off gas supply to prevent personal injury and possible explosions.Features/Specifications: 2-5/8" Square Black Display with LEDs & Silence/Test Button Solenoid Valve & Adapter Solenoid Valve Control Button Automatically Closes Solenoid Valve 68 dBA Alarm will sound & Red LED will light at 20% of the LEL Simple Installation 9-30VDC Operating Temperature: -40°F to 185°F (-40°C to 85°C) Reverse Polarity Protected Current Draw @ 12VDC: Nominal:55mA / Maximum:780mA Specifications: Blower Relay: No Fume Type: Propane Generator Shutdown: No Sensors Included: 2 Voltage - Input Range (Volts): 9-30v Box Dimensions: 4"H x 4"W x 8"L WT: 2 lbs UPC: 619749202684
$865.00 $506.99
-
Fireboy-Xintex Fireboy-Xintex Gasoline Fume Detector w/Dual Channel - 12/24V [G-2B-R]
Gasoline Fume Detector with Dual Channel - 12/24VThe Dual Channel Gasoline Fume Detector is an effective means to monitor gasoline fumes in an engine compartment, fuel tank storage area or in other areas where gasoline fumes might accumulate. Complete system with easy installation and precise monitoring. Features: Simple Installation Audible and visual alarm to indicate LEL (Lower Explosive Level) presence Monitors two (2) separate areas simultaneously Technical Specifications: Operating Temperature: -40° to 185°F (-40° to 85°C) Current Draw Nominal - 55mA Current Draw Maximum - 150mA Operating Voltage - 9 to 30V DC Alarm Horn - 68 dB Display Style - Square with Black Bezel Display Dimensions - 2-5/8" x 2-5/8" (6.7 x 6.7 cm) Cutout Dimension - 2-1/8" (5.4 cm) round hole In the Box: Fume Detector Fuel sensors x two (2) 20' Extension Cable x two (2) Instruction manual *Sold as an Individual Specifications: Blower Relay: No Fume Type: Gasoline Generator Shutdown: No Sensors Included: 2 Voltage - Input Range (Volts): 9 to 30 Box Dimensions: 4"H x 4"W x 8"L WT: 1.5 lbs UPC: 619749202554 Owner's Manual (pdf)Brochure (pdf)
$825.00 $484.99
-
Fireboy-Xintex Fireboy-Xintex Propane Fume Detector w/2 Plastic Sensors - No Solenoid Valve - Square Black Bezel Display [P-2BNV-R]
Propane Fume Detector w/2 Plastic Sensors - No Solenoid Valve - Square Black Bezel DisplayDetect propane leaks early and automatically shut off gas supply to prevent personal injury and possible explosions.Features/Specifications: 2-5/8" Square Black Display with LEDs & Silence/Test Button 68 dBA Alarm will sound & Red LED will light at 20% of the LEL Simple Installation 9-30VDC Operating Temperature: -40°F to 185°F (-40°C to 85°C) Reverse Polarity Protected Current Draw @ 12VDC: Nominal:55mA / Maximum:780mA For use with existing solenoid valve & adapter Specifications: Blower Relay: No Fume Type: Propane Generator Shutdown: No Sensors Included: 2 Voltage - Input Range (Volts): 9-30v Box Dimensions: 4"H x 4"W x 8"L WT: 1.6 lbs UPC: 619749202677
$725.00 $425.99
-
Fireboy-Xintex Fireboy-Xintex Engine Shutdown - 5 Circuit w/20A Relays - Round Display [ES-5000-01]
Engine Shutdown - 5 Circuit with 20A Relays - Round Display If a fire breaks out aboard a diesel-powered vessel, the engine(s) must be shut down prior to or during the discharge of a suppression system to effectively extinguish the fire. Continued engine operation may remove the agent, lowering the concentration required to effectively extinguish the fire, making an Engine Shutdown System necessary. Consisting of a Shutdown Control Module and Helm Display Unit with an Override Button the Fireboy Engine Shutdown System is an effective means to automatically shut down engines, generators, and blower systems in the event of a fire.Technical Specifications: Operating Voltage - 9 to 38 VDC Maximum Current Draw - 310mA @ 12 VDC Operating Temperature - 22°F (-6°C) to 158°F (70°C) Circuits - Five (5) with 20 Amp relays *Sold as an Individual Owner's Manual (pdf)
$700.00 $411.99
-
Fireboy-Xintex Fireboy-Xintex Propane Fume Detector w/Plastic Sensor Solenoid Valve - Chrome Bezel Display [P-1CS-R]
Propane Fume Detector with Plastic Sensor & Solenoid Valve - Chrome Bezel DisplayDetect propane leaks early and automatically shut off gas supply to prevent personal injury and possible explosions.Features: 2-3/16" Round Chrome Display with LEDs & Silence/Test Button Solenoid Valve & Adapter Solenoid Valve Control Button Automatically Closes Solenoid Valve 68 dBA Alarm will sound & Red LED will light at 20% of the LEL Simple Installation 9-30VDC Operating Temperature: -40°F to 185°F (-40°C to 85°C) Reverse Polarity Protected Current Draw @ 12VDC: Nominal: 55mA/Maximum: 725mA Specifications: Blower Relay: No Fume Type: Propane Generator Shutdown: No Sensors Included: 1 Voltage - Input Range (Volts): 9-30v Box Dimensions: 4"H x 4"W x 8"L WT: 1.6 lbs UPC: 619749202660
$615.00 $359.99
-
Fireboy-Xintex Fireboy-Xintex Propane Fume Detector w/Plastic Sensor Solenoid Valve - Black Bezel Display [P-1BS-R]
Propane Fume Detector w/Plastic Sensor & Solenoid Valve - Black Bezel DisplayDetect propane leaks early and automatically shut off gas supply to prevent personal injury and possible explosions.Features/Specifications: 2-3/16" Round Black Display with LEDs & Silence/Test Button Solenoid Valve & Adapter Solenoid Valve Control Button Automatically Closes Solenoid Valve 68 dBA Alarm will sound & Red LED will light at 20% of the LEL Simple Installation 9-30VDC Operating Temperature: -40°F to 185°F (-40°C to 85°C) Reverse Polarity Protected Current Draw @ 12VDC: Nominal:55mA / Maximum:725mA Specifications: Blower Relay: No Fume Type: Propane Generator Shutdown: No Sensors Included: 1 Voltage - Input Range (Volts): 9-30v Box Dimensions: 4"H x 4"W x 8"L WT: 1.6 lbs UPC: 619749202639
$600.00 $352.99
-
Fireboy-Xintex Fireboy-Xintex Engine Shutdown System w/Round Display [ES-3000-01]
Engine Shut Down SystemFeatures: 3 - 20 Amp Circuits 12/24 VDC Engine Shut Down System Round Display Specifications: Blower Relay: No Generator Shutdown: No Sensors Included: 3 Voltage - Input Range (Volts): 12v Box Dimensions: 5"H x 6"W x 12"L WT: 1.55 lbs UPC: 619749211181
$600.00 $352.99
-
Fireboy-Xintex Fireboy-Xintex Gasoline Fume Detector w/Blower Control - Chrome Bezel - 12V [G-1CB-R]
Gasoline Fume Detector w/Blower Control - Chrome Bezel - 12VThe Single Channel Gasoline Fume Detector is an effective means to monitor gasoline fumes in an engine compartment, fuel tank storage area or in other areas where gasoline fumes might accumulate. Complete system includes Blower Control Relay, easy installation and precise monitoring. Features: Simple Installation Audible and visual alarm to indicate LEL (Lower Explosive Level) presence Monitors one (1) single area Automatically activates bilge blower Technical Specifications: Operating Temperature: -40° to 185°F (-40° to 85°C) Current Draw Nominal - 55mA Current Draw Maximum - 95mA Operating Voltage - 9 to 30V DC Alarm Horn - 68 dB Display Style - Round with Chrome Bezel Display Dimensions - 2-3/16" (5.6 cm) round Cutout Dimension - 2-1/16" (5.2 cm) round hole In the Box: Fume Detector Fuel sensors x one (1) 20' Extension Cable x one (1) Blower Relay x one (1) Instruction manual *Sold as an Individual Specifications: Blower Relay: Yes Fume Type: Gasoline Generator Shutdown: No Sensors Included: 1 Voltage - Input Range (Volts): 9 to 30 Box Dimensions: 4"H x 4"W x 8"L WT: 1 lbs UPC: 619749202547 Owner's Manual (pdf)Brochure (pdf)
$540.00 $315.99
-
Fireboy-Xintex Fireboy-Xintex Gasoline Fume Detector w/Blower Control - Black Bezel - 12V [G-1BB-R]
Gasoline Fume Detector w/Blower Control - Black Bezel - 12VThe Single Channel Gasoline Fume Detector is an effective means to monitor gasoline fumes in an engine compartment, fuel tank storage area or in other areas where gasoline fumes might accumulate. Complete system includes Blower Control Relay, easy installation and precise monitoring. Features: Simple Installation Audible and visual alarm to indicate LEL (Lower Explosive Level) presence Monitors one (1) single area Automatically activates bilge blower Technical Specifications: Operating Temperature: -40° to 185°F (-40° to 85°C) Current Draw Nominal - 55mA Current Draw Maximum - 95mA Operating Voltage - 9 to 30V DC Alarm Horn - 68 dB Display Style - Round with Chrome Bezel Display Dimensions - 2-3/16" (5.6 cm) round Cutout Dimension - 2-1/16" (5.2 cm) round hole In the Box: Fume Detector Fuel sensors x one (1) 20' Extension Cable x one (1) Blower Relay x one (1) Instruction manual *Sold as an Individual Specifications: Blower Relay: Yes Fume Type: Gasoline Generator Shutdown: No Sensors Included: 1 Voltage - Input Range (Volts): 9 to 30 Box Dimensions: 4"H x 4"W x 8"L WT: 1 lbs UPC: 619749202523 Owner's Manual (pdf)Brochure (pdf)
$515.00 $301.99
-
Fireboy-Xintex Fireboy-Xintex Propane Fume Detector w/Automatic Shut-Off Plastic Sensor - No Solenoid Valve - Chrome Bezel Display [P-1CNV-R]
Propane Fume Detector w/Automatic Shut-Off & Plastic Sensor - No Solenoid Valve - Chrome Bezel DisplayDetect propane leaks early and automatically shut off gas supply to prevent personal injury and possible explosions.Features/Specifications: 2-3/16" Round Chrome Display with LEDs & Silence/Test Button 68 dBA Alarm will sound & Red LED will light at 20% of the LEL Simple Installation 9-30VDC Operating Temperature: -40°F to 185°F (-40°C to 85°C) Reverse Polarity Protected Current Draw @ 12VDC: Nominal:55mA / Maximum:95mA Specifications: Blower Relay: No Fume Type: Propane Generator Shutdown: No Sensors Included: 1 Voltage - Input Range (Volts): 9-30v Box Dimensions: 4"H x 4"W x 8"L WT: 1 lbs UPC: 619749207450
$515.00 $301.99
-
Fireboy-Xintex Fireboy-Xintex Propane Fume Detector w/Automatic Shut-Off Plastic Sensor - No Solenoid Valve - Black Bezel Display [P-1BNV-R]
Propane Fume Detector w/Automatic Shut-Off & Plastic Sensor - No Solenoid Valve - Black Bezel DisplayDetect propane leaks early and automatically shut off gas supply to prevent personal injury and possible explosions.Features/Specifications: 2-3/16" Round Black Display with LEDs & Silence/Test Button 68 dBA Alarm will sound & Red LED will light at 20% of the LEL Simple Installation 9-30VDC Operating Temperature: -40°F to 185°F (-40°C to 85°C) Reverse Polarity Protected Current Draw @ 12VDC: Nominal:55mA / Maximum:95mA Specifications: Blower Relay: No Fume Type: Propane Generator Shutdown: No Sensors Included: 1 Voltage - Input Range (Volts): 9-30v Box Dimensions: 4"H x 4"W x 8"L WT: 1 lbs UPC: 619749207443
$500.00 $293.99
-
Fireboy-Xintex Fireboy-Xintex Propane Fume Detector w/Plastic Sensor - No Solenoid Valve - Chrome Bezel Displa [P-1C-R]
Propane Fume Detector w/Plastic Sensor - No Solenoid Valve - Chrome Bezel DisplayDetect Propane leaks early to prevent personal injury and possible explosions.Features/Specifications: 2-3/16" Round Chrome Display with LEDs & Silence/Test Button 68 dBA Alarm will sound & Red LED will light at 20% of the LEL Simple Installation 9-30VDC Operating Temperature: -40°F to 185°F (-40°C to 85°C) Reverse Polarity Protected Current Draw @ 12VDC: Nominal:55mA / Maximum:95mA Specifications: Blower Relay: No Fume Type: Propane Generator Shutdown: No Sensors Included: 1 Voltage - Input Range (Volts): 9-30v Box Dimensions: 4"H x 4"W x 8"L WT: 1 lbs UPC: 619749202653
$500.00 $293.99
-
Fireboy-Xintex Fireboy-Xintex Gasoline Fume Detector - Chrome Bezel - 12/24V [G-1C-R]
Gasoline Fume Detector - Chrome Bezel - 12/24VThe Single Channel Gasoline Fume Detector is an effective means to monitor gasoline fumes in an engine compartment, fuel tank storage area or in other areas where gasoline fumes might accumulate. Features: Simple Installation Audible and visual alarm to indicate LEL (Lower Explosive Level) presence Monitors one (1) single area Technical Specifications: Operating Temperature: -40° to 185°F (-40° to 85°C) Current Draw Nominal - 55mA Current Draw Maximum - 95mA Operating Voltage - 9 to 30V DC Alarm Horn - 68 dB Display Style - Round with Chrome Bezel Display Dimensions - 2-3/16" (5.6 cm) round Cutout Dimension - 2-1/16" (5.2 cm) round hole In the Box: Fume Detector Fuel sensors x one (1) 20' Extension Cable x one (1) Instruction manual *Sold as an Individual Specifications: Blower Relay: No Fume Type: Gasoline Generator Shutdown: No Sensors Included: 1 Voltage - Input Range (Volts): 9 to 30 Box Dimensions: 4"H x 4"W x 8"L WT: 1 lbs UPC: 619749202530 Owner's Manual (pdf)Brochure (pdf)
$490.00 $286.99
-
Fireboy-Xintex Fireboy-Xintex Propane Fume Detector w/Plastic Sensor - No Solenoid Valve - Black Bezel Display [P-1B-R]
Propane Fume Detector w/Plastic Sensor - No Solenoid Valve - Black Bezel DisplayDetect Propane leaks early to prevent personal injury and possible explosions.Features/Specifications: 2-3/16" Round Black Display with LEDs & Silence/Test Button 68 dBA Alarm will sound & Red LED will light at 20% of the LEL Simple Installation 9-30VDC Operating Temperature: -40°F to 185°F (-40°C to 85°C) Reverse Polarity Protected Current Draw @ 12VDC: Nominal:55mA / Maximum:95mA Specifications: Blower Relay: No Fume Type: Propane Generator Shutdown: No Sensors Included: 1 Voltage - Input Range (Volts): 9-30v Box Dimensions: 4"H x 4"W x 8"L WT: 1.6 lbs UPC: 619749202646
$490.00 $286.99
-
Fireboy-Xintex Fireboy-Xintex Gasoline Fume Detector - Black Bezel - 12/24V [G-1B-R]
Gasoline Fume Detector - Black Bezel - 12/24VThe Single Channel Gasoline Fume Detector is an effective means to monitor gasoline fumes in an engine compartment, fuel tank storage area or in other areas where gasoline fumes might accumulate. Features: Simple Installation Audible and visual alarm to indicate LEL (Lower Explosive Level) presence Monitors one (1) single area Technical Specifications: Operating Temperature: -40° to 185°F (-40° to 85°C) Current Draw Nominal - 55mA Current Draw Maximum - 95mA Operating Voltage - 9 to 30V DC Alarm Horn - 68 dB Display Style - Round with Black Bezel Display Dimensions - 2-3/16" (5.6 cm) round Cutout Dimension - 2-1/16" (5.2 cm) round hole In the Box: Fume Detector Fuel sensors x one (1) 20' Extension Cable x one (1) Instruction manual *Sold as an Individual Specifications: Blower Relay: No Fume Type: Gasoline Generator Shutdown: No Sensors Included: 1 Voltage - Input Range (Volts): 9 to 30 Box Dimensions: 4"H x 4"W x 8"L WT: 1 lbs UPC: 619749202516 Owner's Manual (pdf)Brochure (pdf)
$475.00 $279.99
-
Fireboy-Xintex Fireboy-Xintex Manual Discharge Cable Kit - 50 [E-4209-50]
Manual Discharge Cable Kit - 50'Designed for manual activation of the MA and GA Series of fire suppression systems. The manual discharge cable kit is a backup for those who prefer the extra measure of control or for inspected vessels who are required by U.S. Coast Guard regulation. Compatible With:MA, MU, MA2, GA, GA1 and GA2 Series of fire suppression systemsFeatures: Easily routed with engine cables and electrical wiring Various lengths for vessel specific installation In the Box: Cable - 50' Mounting plate Pull handle Safety pin *Sold as an Individual Specifications:Type: Parts
$425.00 $249.99
-
Fireboy-Xintex Fireboy-Xintex Manual Discharge Cable Kit - 42 [E-4209-42]
Manual Discharge Cable Kit - 42' Designed for manual activation of the MA and GA Series of fire suppression systems. The manual discharge cable kit is a backup for those who prefer the extra measure of control or for inspected vessels who are required by U.S. Coast Guard regulation. Compatible With:MA, MU, MA2, GA, GA1 and GA2 Series of fire suppression systemsFeatures: Easily routed with engine cables and electrical wiring Various lengths for vessel specific installation In the Box: Cable - 42' Mounting plate Pull handle Safety pin *Sold as an Individual Specifications:Type: Parts
$390.00 $227.99
-
Fireboy-Xintex Fireboy-Xintex Manual Discharge Cable Kit - 36 [E-4209-36]
Manual Discharge Cable Kit - 36'Designed for manual activation of the MA and GA Series of fire suppression systems. The manual discharge cable kit is a backup for those who prefer the extra measure of control or for inspected vessels who are required by U.S. Coast Guard regulation. Compatible With:MA, MU, MA2, GA, GA1 and GA2 Series of fire suppression systemsFeatures: Easily routed with engine cables and electrical wiring Various lengths for vessel specific installation In the Box: Cable - 36' Mounting plate Pull handle Safety pin *Sold as an Individual Specifications: Type: Parts Box Dimensions: 3"H x 18"W x 18"L WT: 4 lbs UPC: 619749311324
$355.00 $207.99
-
Fireboy-Xintex Fireboy-Xintex Propane Control Solenoid Valve w/Chrome Bezel Display [C-1C-R]
Propane Control & Solenoid Valve w/Chrome Bezel DisplayMinimize the risk of personal injury and possible explosions! Conveniently turn off the gas supply at the source with the push of a button when not in use.Features/Specifications: Compact Design 2-3/16" Round Chrome Bezel Solenoid Valve Simple Installation 9-30VDC Operating Temperature: -40°F to 185°F (-40°C to 85°C) Reverse Polarity Current Draw @ 12 VDC: Nominal:20mA / Maximum:650mA Specifications: Blower Relay: No Fume Type: Propane Generator Shutdown: No Voltage - Input Range (Volts): 9-30v Box Dimensions: 4"H x 4"W x 9"L WT: 0.8 lbs UPC: 619749202226
$340.00 $198.99
-
Fireboy-Xintex Fireboy-Xintex Propane Control Solenoid Valve w/Black Bezel Display [C-1B-R]
Propane Control & Solenoid Valve w/Black Bezel DisplayMinimize the risk of personal injury and possible explosions! Conveniently turn off the gas supply at the source with the push of a button when not in use.Features/Specifications: Compact Design 2-3/16" Round Black Bezel Solenoid Valve Simple Installation 9-30VDC Operating Temperature: -40°F to 185°F (-40°C to 85°C) Reverse Polarity Current Draw @ 12 VDC: Nominal:20mA / Maximum:650mA Specifications: Blower Relay: No Fume Type: Propane Generator Shutdown: No Voltage - Input Range (Volts): 9-30v Box Dimensions: 4"H x 4"W x 8"L WT: 1.2 lbs UPC: 619749202219
$300.00 $176.99
-
Fireboy-Xintex Fireboy-Xintex Propane Gasoline Sensor w/Cable - Aluminum Housing [FS-A01-R]
Propane & Gasoline Sensor with Cable - Aluminum Housing Gasoline & propane sensor with 12" lead and 20' sensor cable. Compatible With: G-1 Gasoline Fume Detector G-2 Gasoline Fume Detector P-1 Propane Fume Detector P-2 Propane Fume Detector *Sold as an Individual Specifications: Type: Parts Box Dimensions: 4"H x 4"W x 5"L WT: 0.7 lbs UPC: 619749202349
$290.00 $168.99
-
Fireboy-Xintex Fireboy-Xintex Manual Discharge Cable Kit - 28 [E-4209-28]
Manual Discharge Cable Kit - 28'Designed for manual activation of the MA and GA Series of fire suppression systems. The manual discharge cable kit is a backup for those who prefer the extra measure of control or for inspected vessels who are required by U.S. Coast Guard regulation. Compatible With:MA, MU, MA2, GA, GA1 and GA2 Series of fire suppression systemsFeatures: Easily routed with engine cables and electrical wiring Various lengths for vessel specific installation In the Box: Cable - 28' Mounting plate Pull handle Safety pin *Sold as an Individual Specifications:Type: Parts
$275.00 $161.99
-
Fireboy-Xintex Fireboy-Xintex Propane Gasoline Sensor w/Cable - Red Plastic Housing [FS-T01-R]
Propane & Gasoline Sensor with Cable - Red Plastic Housing Gasoline & propane sensor with 12" lead and 20' sensor cable.Compatible With: G-1 Gasoline Fume Detector G-2 Gasoline Fume Detector P-1 Propane Fume Detector P-2 Propane Fume Detector *Sold as an Individual Specifications: Type: Parts Box Dimensions: 4"H x 4"W x 6"L WT: 0.7 lbs UPC: 619749202363
$265.00 $154.99
-
Fireboy-Xintex Fireboy-Xintex Manual Discharge Cable Kit - 24 [E-4209-24]
Manual Discharge Cable Kit - 24'Designed for manual activation of the MA and GA Series of fire suppression systems. The manual discharge cable kit is a backup for those who prefer the extra measure of control or for inspected vessels who are required by U.S. Coast Guard regulation. Compatible With:MA, MU, MA2, GA, GA1 and GA2 Series of fire suppression systemsFeatures: Easily routed with engine cables and electrical wiring Various lengths for vessel specific installation In the Box: Cable - 24' Mounting plate Pull handle Safety pin *Sold as an Individual Specifications:Type: Parts
$250.00 $146.99
-
Fireboy-Xintex Fireboy-Xintex CO Alarm Relay Control Module [RCM5]
CO Alarm Relay Control ModuleThe RCM5 is a Relay Control Module. It allows you to automatically deactivate devices based on the status of the connected Xintex detection device. The RCM5 uses a signal provided by the connected Xintex device to activate the internal relay. This allows you to shutdown generators or other devices automatically.Compatible With:Interconnect models onlyTechnical Specifications: Material - Flame retardant ABS plastic Dimensions (L x W x H) - 3.1" x 2.1" x 1.83" (7.6 x 5.2 x 4.6 cm) Operating Voltage - 9 - 32V DC *Sold as an Individual Owner's Manual (pdf)
$250.00 $146.99
-
Fireboy-Xintex Fireboy-Xintex Deluxe Helm Display w/Membrane Switch, Remote Horn LEDs f/Engine Shutdown System - Black Bezel Display [DU-SBH-20-R]
Deluxe Helm Display w/Membrane Switch, Remote Horn & LEDs f/Engine Shutdown System - Black Bezel DisplayFeatures/Specifications: Compact Design 2-5/8" Square Black Bezel Simple Installation 9-30VDC Operating Temperature: -40°F to 185°F (-40°C to 85°C) Reverse Polarity Protected Specifications: Blower Relay: No Generator Shutdown: No Voltage - Input Range (Volts): 9-30v Box Dimensions: 4"H x 5"W x 7"L WT: 0.4 lbs UPC: 619749207269
$250.00 $146.99
-
Fireboy-Xintex Fireboy-Xintex Deluxe Helm Display w/Gauge Body, LED Color Graphics f/Engine Shutdown System - Chrome Bezel Display [DU-RCH-20-R]
Deluxe Helm Display w/Gauge Body, LED & Color Graphics f/Engine Shutdown System - Chrome Bezel DisplayFeatures/Specifications: Compact Design 2-3/16" Round Chrome Bezel Simple Installation 9-30VDC Operating Temperature: -40°F to 185°F (-40°C to 85°C) Reverse Polarity Protected Specifications: Blower Relay: No Generator Shutdown: No Voltage - Input Range (Volts): 9-30v Box Dimensions: 4"H x 5"W x 7"L WT: 0.4 lbs UPC: 619749207252
$250.00 $146.99
-
Fireboy-Xintex Fireboy-Xintex Deluxe Helm Display w/Gauge Body, LED Color Graphics f/Engine Shutdown System - Black Bezel Display [DU-RBH-20-R]
Deluxe Helm Display w/Gauge Body, LED & Color Graphics f/Engine Shutdown System - Black Bezel DisplayFeatures/Specifications: Compact Design 2-3/16" Round Black Bezel Simple Installation 9-30VDC Operating Temperature: -40°F to 185°F (-40°C to 85°C) Reverse Polarity Protected Specifications: Blower Relay: No Generator Shutdown: No Voltage - Input Range (Volts): 9-30v Box Dimensions: 4"H x 5"W x 7"L WT: 0.3 lbs UPC: 619749207245
$240.00 $139.99
-
Fireboy-Xintex Fireboy-Xintex CO Alarm Internal Battery w/Interconnect - White [CMD6-MBR-R]
CO Alarm Internal Battery w/Interconnect - WhiteA Carbon Monoxide (CO) detector should be installed in each accommodation space. Small crafts or RV's with an open design may require only one (1) detector for adequate protection. If two (2) or more sleeping areas or spaces are partitioned, then one (1) detector should be installed in each of the spaces.The Fireboy-Xintex CMD6-M Series CO alarm uses a sensor operating with a microprocessor to measure Carbon Monoxide (CO) levels. Using a “Time Weighted Average” (TWA) process, it monitors CO concentration, temperature and time to calculate levels of Carboxyhemoglobin (COHb). COHb is the degree to which the oxygen carrying capacity of the blood is impeded by the union of carbon monoxide to the hemoglobin and as expressed as a percentage. The human body absorbs CO easier than oxygen and COHb is the ratio absorbed carbon monoxide to oxygen in bloodstream. The CMD6-M alarm calculates the COHb as function of time and determines the appropriate alarm response.*Long sensor life – approximately 7 year end-of-life (EOL)Features: Interconnect up to ten (10) CO alarms - all connected CO alarms sound together Microprocessor controlled Compact design for inconspicuous protection Time-weighted average CO measurement process constantly monitors all CO levels Highly resistant to most chemicals, solvents & cleaners CMD6-MD Internal battery model uses included maintenance-free lithium-metal batteries. No wiring and reduced labor and material costs to install. Technical Specifications: Power Usage - None Alarm Point - 10% COHb Alarm Horn - 85 dBA Dimensions - .5" x 3.5" x 1.21" (8.9 x 8.9 x 3.1 cm) Interconnect Functionality - Yes *Sold as an Individual Specifications: Blower Relay: No Fume Type: Carbon Monoxide Generator Shutdown: No Sensors Included: 1 Voltage - Input Range (Volts): N/A Box Dimensions: 2"H x 4"W x 6"L WT: 0.4 lbs UPC: 619749208693 Owner's Manual (pdf)Brochure (pdf)
$230.00 $135.99
-
Fireboy-Xintex Fireboy-Xintex CO Alarm 12/24V DC w/Interconnect - White [CMD6-MDR-R]
CO Alarm 12/24V DC with Interconnect - Black A Carbon Monoxide (CO) detector should be installed in each accommodation space. Small crafts or RV's with an open design may require only one (1) detector for adequate protection. If two (2) or more sleeping areas or spaces are partitioned, then one (1) detector should be installed in each of the spaces.The Fireboy-Xintex CMD6-M Series CO alarm uses a sensor operating with a microprocessor to measure Carbon Monoxide (CO) levels. Using a “Time Weighted Average” (TWA) process, it monitors CO concentration, temperature and time to calculate levels of Carboxyhemoglobin (COHb). COHb is the degree to which the oxygen carrying capacity of the blood is impeded by the union of carbon monoxide to the hemoglobin and as expressed as a percentage. The human body absorbs CO easier than oxygen and COHb is the ratio absorbed carbon monoxide to oxygen in bloodstream. The CMD6-M alarm calculates the COHb as function of time and determines the appropriate alarm response.*Long sensor life – approximately 7 year end-of-life (EOL)Features: Interconnect up to ten (10) CO alarms - all connected CO alarms sound together Microprocessor controlled Compact design for inconspicuous protection Time-weighted average CO measurement process constantly monitors all CO levels Highly resistant to most chemicals, solvents & cleaners CMD6-MD 12/24V DC model uses boat power and has permanent internal backup Lithium-metal batteries Technical Specifications: Power Usage - 4 mA Alarm Point - 10% COHb Alarm Horn - 85 dBA Dimensions - .5" x 3.5" x 1.21" (8.9 x 8.9 x 3.1 cm) Interconnect Functionality - Yes *Sold as an Individual Specifications: Blower Relay: No Fume Type: Carbon Monoxide Generator Shutdown: No Sensors Included: 1 Voltage - Input Range (Volts): 12 - 24 Box Dimensions: 2"H x 4"W x 6"L WT: 0.4 lbs UPC: 619749208853 Owner's Manual (pdf)Brochure (pdf)
$230.00 $135.99
-
Fireboy-Xintex Fireboy-Xintex CO Alarm Internal Battery w/Interconnect - Black [CMD6-MBR-BR]
CO Alarm Internal Battery w/Interconnect - BlackA Carbon Monoxide (CO) detector should be installed in each accommodation space. Small crafts or RV's with an open design may require only one (1) detector for adequate protection. If two (2) or more sleeping areas or spaces are partitioned, then one (1) detector should be installed in each of the spaces.The Fireboy-Xintex CMD6-M Series CO alarm uses a sensor operating with a microprocessor to measure Carbon Monoxide (CO) levels. Using a “Time Weighted Average” (TWA) process, it monitors CO concentration, temperature and time to calculate levels of Carboxyhemoglobin (COHb). COHb is the degree to which the oxygen carrying capacity of the blood is impeded by the union of carbon monoxide to the hemoglobin and as expressed as a percentage. The human body absorbs CO easier than oxygen and COHb is the ratio absorbed carbon monoxide to oxygen in bloodstream. The CMD6-M alarm calculates the COHb as function of time and determines the appropriate alarm response.*Long sensor life – approximately 7 year end-of-life (EOL)Features: Interconnect up to ten (10) CO alarms - all connected CO alarms sound together Microprocessor controlled Compact design for inconspicuous protection Time-weighted average CO measurement process constantly monitors all CO levels Highly resistant to most chemicals, solvents & cleaners CMD6-MD Internal battery model uses included maintenance-free lithium-metal batteries. No wiring and reduced labor and material costs to install. Technical Specifications: Power Usage - None Alarm Point - 10% COHb Alarm Horn - 85 dBA Dimensions - .5" x 3.5" x 1.21" (8.9 x 8.9 x 3.1 cm) Interconnect Functionality - Yes *Sold as an Individual Specifications: Blower Relay: No Fume Type: Carbon Monoxide Generator Shutdown: Yes Sensors Included: 1 Voltage - Input Range (Volts): N/A Box Dimensions: 2"H x 4"W x 6"L WT: 0.4 lbs UPC: 619749208686 Owner's Manual (pdf)Brochure (pdf)
$230.00 $135.99
-
Fireboy-Xintex Fireboy-Xintex CO Alarm 12/24V DC w/Interconnect - Black [CMD6-MDR-BR]
CO Alarm 12/24V DC with Interconnect - Black A Carbon Monoxide (CO) detector should be installed in each accommodation space. Small crafts or RV's with an open design may require only one (1) detector for adequate protection. If two (2) or more sleeping areas or spaces are partitioned, then one (1) detector should be installed in each of the spaces.The Fireboy-Xintex CMD6-M Series CO alarm uses a sensor operating with a microprocessor to measure Carbon Monoxide (CO) levels. Using a “Time Weighted Average” (TWA) process, it monitors CO concentration, temperature and time to calculate levels of Carboxyhemoglobin (COHb). COHb is the degree to which the oxygen carrying capacity of the blood is impeded by the union of carbon monoxide to the hemoglobin and as expressed as a percentage. The human body absorbs CO easier than oxygen and COHb is the ratio absorbed carbon monoxide to oxygen in bloodstream. The CMD6-M alarm calculates the COHb as function of time and determines the appropriate alarm response.*Long sensor life – approximately 7 year end-of-life (EOL)Features: Interconnect up to ten (10) CO alarms - all connected CO alarms sound together Microprocessor controlled Compact design for inconspicuous protection Time-weighted average CO measurement process constantly monitors all CO levels Highly resistant to most chemicals, solvents & cleaners CMD6-MD 12/24V DC model uses boat power and has permanent internal backup Lithium-metal batteries Technical Specifications: Power Usage - 4 mA Alarm Point - 10% COHb Alarm Horn - 85 dBA Dimensions - .5" x 3.5" x 1.21" (8.9 x 8.9 x 3.1 cm) Interconnect Functionality - Yes *Sold as an Individual Specifications: Blower Relay: No Fume Type: Carbon Monoxide Generator Shutdown: No Sensors Included: 1 Voltage - Input Range (Volts): 12 - 24 Box Dimensions: 2"H x 4"W x 6"L WT: 0.4 lbs UPC: 619749208846 Owner's Manual (pdf)Brochure (pdf)
$230.00 $135.99
-
Fireboy-Xintex Fireboy-Xintex Optical Smoke Detector w/Base [OMSD-01-DB-R]
Optical Smoke Detector with BaseOptical smoke detectors have consistently been recognized as suitable detectors for general use. They are regarded as particularly suitable for smoldering fires and escape routes. This smoke detector is also designed to significantly reduce the incidence of false alarms through over-sensitivity to transient phenomena.Features: Recommended for use as general-purpose smoke detectors for early warning of fires in most areas Works well in black as well as in white smoke Compensation for slow changes in sensitivity Extra confirmation of smoke before an alarm signal is given Specifications: Sampling Frequency: Once every four seconds Operating Voltage: 8.5 V dc to 33 V dc Supply Wiring: Two wire supply, polarity sensitive Power-up Time: < 20 seconds Minimum ‘Detector Active’ Voltage: 6 V Minimum Holding Current: 8 mA Minimum Voltage to Light Alarm LED: 5 V Alarm Reset Time: One second Alarm Indicator: Integral indicator with 360º visibility Operating & Storage Temperature: -40ºC to +70ºC Humidity (no condensation or icing): 0% to 98% RH Operation: Optical Smoke Detectors work on the well-established light scatter principle The remarkable optical design of this Smoke Detector enables it to respond to a wide spectrum of fires The sensing chamber contains an optical sensor that measures back-scattered light as well as the more usual forward-scattered light The detector is calibrated so that it is highly reliable in detecting fires but is much less likely to generate false alarms The stability of the detector-high reliability, low false alarm rate is further increased by the use of algorithms to decide when the detector should change to the alarm state Removes the likelihood of a detector producing an alarm as a result of smoke from smoking materials or another non-fire source Specifications: Fume Type: Smoke Box Dimensions: 2"H x 5"W x 7"L WT: 0.35 lbs UPC: 619749321095
$225.00 $132.99
-
Fireboy-Xintex Fireboy-Xintex Manual Discharge Cable Kit - 20 [E-4209-20]
Manual Discharge Cable Kit - 20'Designed for manual activation of the MA and GA Series of fire suppression systems. The manual discharge cable kit is a backup for those who prefer the extra measure of control or for inspected vessels who are required by U.S. Coast Guard regulation. Compatible With:MA, MU, MA2, GA, GA1 and GA2 Series of fire suppression systemsFeatures: Easily routed with engine cables and electrical wiring Various lengths for vessel specific installation In the Box: Cable - 20' Mounting plate Pull handle Safety pin *Sold as an Individual Specifications: Type: Parts Box Dimensions: 3"H x 18"W x 18"L WT: 2.55 lbs UPC: 619749311225
$220.00 $129.99
-
Fireboy-Xintex Fireboy-Xintex Manual Discharge Cable Kit - 16 [E-4209-16]
Manual Discharge Cable Kit - 16'Designed for manual activation of the MA and GA Series of fire suppression systems. The manual discharge cable kit is a backup for those who prefer the extra measure of control or for inspected vessels who are required by U.S. Coast Guard regulation. Compatible With:MA, MU, MA2, GA, GA1 and GA2 Series of fire suppression systemsFeatures: Easily routed with engine cables and electrical wiring Various lengths for vessel specific installation In the Box: Cable - 16' Mounting plate Pull handle Safety pin *Sold as an Individual Specifications: Type: Parts Box Dimensions: 2"H x 17"W x 17"L WT: 2.2 lbs UPC: 619749311201
$208.00 $120.99
-
Fireboy-Xintex Fireboy-Xintex CO Alarm Internal Battery - White [CMD6-MB-R]
CO Alarm Internal Battery - WhiteA Carbon Monoxide (CO) detector should be installed in each accommodation space. Small crafts or RV's with an open design may require only one (1) detector for adequate protection. If two (2) or more sleeping areas or spaces are partitioned, then one (1) detector should be installed in each of the spaces.The Fireboy-Xintex CMD6-M Series CO alarm uses a sensor operating with a microprocessor to measure Carbon Monoxide (CO) levels. Using a “Time Weighted Average” (TWA) process, it monitors CO concentration, temperature and time to calculate levels of Carboxyhemoglobin (COHb). COHb is the degree to which the oxygen carrying capacity of the blood is impeded by the union of carbon monoxide to the hemoglobin and as expressed as a percentage. The human body absorbs CO easier than oxygen and COHb is the ratio absorbed carbon monoxide to oxygen in bloodstream. The CMD6-M alarm calculates the COHb as function of time and determines the appropriate alarm response.*Long sensor life – approximately 7 year end-of-life (EOL)Features: Microprocessor controlled Compact design for inconspicuous protection Time-weighted average CO measurement process constantly monitors all CO levels Highly resistant to most chemicals, solvents & cleaners CMD6-MD Internal battery model uses included maintenance-free lithium-metal batteries. No wiring and reduced labor and material costs to install. Technical Specifications: Power Usage - None Alarm Point - 10% COHb Alarm Horn - 85 dBA Dimensions - .5" x 3.5" x 1.21" (8.9 x 8.9 x 3.1 cm) Interconnect Functionality - No *Sold as an Individual Specifications: Blower Relay: No Fume Type: Carbon Monoxide Generator Shutdown: No Sensors Included: 1 Voltage - Input Range (Volts): N/A Box Dimensions: 2"H x 4"W x 4"L WT: 1 lbs UPC: 619749208662 Owner's Manual (pdf)Brochure (pdf)
$205.00 $120.99
-
Fireboy-Xintex Fireboy-Xintex CO Alarm 12/24V DC - White [CMD6-MD-R]
CO Alarm 12/24V DC - WhiteA Carbon Monoxide (CO) detector should be installed in each accommodation space. Small crafts or RV's with an open design may require only one (1) detector for adequate protection. If two (2) or more sleeping areas or spaces are partitioned, then one (1) detector should be installed in each of the spaces.The Fireboy-Xintex CMD6-M Series CO alarm uses a sensor operating with a microprocessor to measure Carbon Monoxide (CO) levels. Using a “Time Weighted Average” (TWA) process, it monitors CO concentration, temperature and time to calculate levels of Carboxyhemoglobin (COHb). COHb is the degree to which the oxygen carrying capacity of the blood is impeded by the union of carbon monoxide to the hemoglobin and as expressed as a percentage. The human body absorbs CO easier than oxygen and COHb is the ratio absorbed carbon monoxide to oxygen in bloodstream. The CMD6-M alarm calculates the COHb as function of time and determines the appropriate alarm response.*Long sensor life – approximately 7 year end-of-life (EOL)Features: Microprocessor controlled Compact design for inconspicuous protection Time-weighted average CO measurement process constantly monitors all CO levels Highly resistant to most chemicals, solvents & cleaners CMD6-MD 12/24V DC model uses boat power and has permanent internal backup Lithium-metal batteries Technical Specifications: Power Usage - 4 mA Alarm Point - 10% COHb Alarm Horn - 85 dBA Dimensions - .5" x 3.5" x 1.21" (8.9 x 8.9 x 3.1 cm) Interconnect Functionality - No *Sold as an Individual Specifications: Blower Relay: No Fume Type: Carbon Monoxide Generator Shutdown: No Sensors Included: 1 Voltage - Input Range (Volts): 12 - 24 Box Dimensions: 2"H x 4"W x 4"L WT: 1 lbs UPC: 619749208822 Owner's Manual (pdf)Brochure (pdf)
$205.00 $120.99
-
Fireboy-Xintex Fireboy-Xintex CO Alarm Internal Battery - Black [CMD6-MB-BR]
CO Alarm Internal Battery - BlackA Carbon Monoxide (CO) detector should be installed in each accommodation space. Small crafts or RV's with an open design may require only one (1) detector for adequate protection. If two (2) or more sleeping areas or spaces are partitioned, then one (1) detector should be installed in each of the spaces.The Fireboy-Xintex CMD6-M Series CO alarm uses a sensor operating with a microprocessor to measure Carbon Monoxide (CO) levels. Using a “Time Weighted Average” (TWA) process, it monitors CO concentration, temperature and time to calculate levels of Carboxyhemoglobin (COHb). COHb is the degree to which the oxygen carrying capacity of the blood is impeded by the union of carbon monoxide to the hemoglobin and as expressed as a percentage. The human body absorbs CO easier than oxygen and COHb is the ratio absorbed carbon monoxide to oxygen in bloodstream. The CMD6-M alarm calculates the COHb as function of time and determines the appropriate alarm response.*Long sensor life – approximately 7 year end-of-life (EOL)Features: Microprocessor controlled Compact design for inconspicuous protection Time-weighted average CO measurement process constantly monitors all CO levels Highly resistant to most chemicals, solvents & cleaners CMD6-MD Internal battery model uses included maintenance-free lithium-metal batteries. No wiring and reduced labor and material costs to install. Technical Specifications: Power Usage - None Alarm Point - 10% COHb Alarm Horn - 85 dBA Dimensions - .5" x 3.5" x 1.21" (8.9 x 8.9 x 3.1 cm) Interconnect Functionality - No *Sold as an Individual Specifications: Blower Relay: No Fume Type: Carbon Monoxide Generator Shutdown: No Sensors Included: 1 Voltage - Input Range (Volts): N/A Box Dimensions: 2"H x 4"W x 5"L WT: 0.35 lbs UPC: 619749208563 Owner's Manual (pdf)Brochure (pdf)
$205.00 $120.99
-
Fireboy-Xintex Fireboy-Xintex CO Alarm 12/24V DC - Black [CMD6-MD-BR]
CO Alarm 12/24V DC - BlackA Carbon Monoxide (CO) detector should be installed in each accommodation space. Small crafts or RV's with an open design may require only one (1) detector for adequate protection. If two (2) or more sleeping areas or spaces are partitioned, then one (1) detector should be installed in each of the spaces.The Fireboy-Xintex CMD6-M Series CO alarm uses a sensor operating with a microprocessor to measure Carbon Monoxide (CO) levels. Using a “Time Weighted Average” (TWA) process, it monitors CO concentration, temperature and time to calculate levels of Carboxyhemoglobin (COHb). COHb is the degree to which the oxygen carrying capacity of the blood is impeded by the union of carbon monoxide to the hemoglobin and as expressed as a percentage. The human body absorbs CO easier than oxygen and COHb is the ratio absorbed carbon monoxide to oxygen in bloodstream. The CMD6-M alarm calculates the COHb as function of time and determines the appropriate alarm response.*Long sensor life – approximately 7 year end-of-life (EOL)Features: Microprocessor controlled Compact design for inconspicuous protection Time-weighted average CO measurement process constantly monitors all CO levels Highly resistant to most chemicals, solvents & cleaners CMD6-MD 12/24V DC model uses boat power and has permanent internal backup Lithium-metal batteries Technical Specifications: Power Usage - 4 mA Alarm Point - 10% COHb Alarm Horn - 85 dBA Dimensions - .5" x 3.5" x 1.21" (8.9 x 8.9 x 3.1 cm) Interconnect Functionality - No *Sold as an Individual Specifications: Blower Relay: No Fume Type: Carbon Monoxide Generator Shutdown: No Sensors Included: 1 Voltage - Input Range (Volts): 12 - 24 Box Dimensions: 2"H x 4"W x 6"L WT: 0.4 lbs UPC: 619749208723 Owner's Manual (pdf)Brochure (pdf)
$205.00 $120.99
-
Fireboy-Xintex Fireboy-Xintex Manual Discharge Cable Kit - 14 [E-4209-14]
Manual Discharge Cable Kit - 14'Designed for manual activation of the MA and GA Series of fire suppression systems. The manual discharge cable kit is a backup for those who prefer the extra measure of control or for inspected vessels who are required by U.S. Coast Guard regulation. Compatible With:MA, MU, MA2, GA, GA1 and GA2 Series of fire suppression systemsFeatures: Easily routed with engine cables and electrical wiring Various lengths for vessel specific installation In the Box: Cable - 14' Mounting plate Pull handle Safety pin *Sold as an Individual Specifications: Type: Parts Box Dimensions: 2"H x 18"W x 18"L WT: 2.2 lbs UPC: 619749311188
$204.00 $118.99
-
Fireboy-Xintex Fireboy-Xintex Gasoline Propane Sensor Only [FS-T01-S-R]
Gasoline & Propane Sensor OnlyThis sensor is a replacement for Fireboy-Xintex P systems. Installation: The sensor should be located by the propane-powered appliance, near the floor Avoid areas where damage may take place due to cleaning, mopping, kicking, or other physical damage Harsh chemicals should not be used to clean sensors Use the appropriate #8 mounting hardware to mount the Propane Fume Sensor in the desired location The rubber gasket should be installed between the sensor and the mounting surface Connect to the extension cable using the attached quick-disconnect connectors (Sold Separately)
$200.00 $117.99
-
Fireboy-Xintex Fireboy-Xintex Fixed Heat Detector w/Base [OMHD-04-DB-R]
Fixed Heat Detector with BaseThe Fireboy-Xintex Heat Detector uses a single thermistor to sense the air temperature around the detector. This heat detector was designed to detect how fast the temperature is increasing.Features: 163°F Fixed Heat Detector Housing: White flame-retardant polycarbonate Terminals: Nickel-plated stainless steel Ideal in environments that are dirty or smoky Unaffected by wind or atmospheric pressure Remote test feature Specifications: Detection Principle: Measurement of heat using a thermistor Sampling Frequency: Once every four seconds Supply Voltage: 8.5 V dc to 33 V dc Supply Wiring: Two wire supply, polarity sensitive Power-up Time: < 20 seconds Minimum: ‘detector active’ voltage: 6 V Holding Voltage: 5 V - 33 V Minimum Holding Current: 8 mA Minimum Voltage to Light Alarm LED: 5 V Alarm Reset Voltage: < 1 V Alarm Reset Time: One second Alarm Indicator: Integral indicator with 360º visibility Operating & Storage Temperature: -40ºC to +70ºC Operation: Open-web casing that enables air to flow freely across a thermistor which measures the air temperature every two seconds A microprocessor stores the temperatures and compares them with pre-set values to determine whether a fixed upper limit - the alarm level - has been reached Detectors the microprocessor uses algorithms to determine how fast the temperature is increasing
$200.00 $116.99
-
Fireboy-Xintex Fireboy-Xintex Manual Discharge Cable Kit - 10 [E-4209-10]
Manual Discharge Cable Kit - 10'Designed for manual activation of the MA and GA Series of fire suppression systems. The manual discharge cable kit is a backup for those who prefer the extra measure of control or for inspected vessels who are required by U.S. Coast Guard regulation. Compatible With:MA, MU, MA2, GA, GA1 and GA2 Series of fire suppression systemsFeatures: Easily routed with engine cables and electrical wiring Various lengths for vessel specific installation In the Box: Cable - 10' Mounting plate Pull handle Safety pin *Sold as an Individual Specifications: Type: Parts Box Dimensions: 2"H x 17"W x 18"L WT: 0.7 lbs UPC: 619749311164
$190.00 $110.99
You have seen 48 out of 57 products
